FinloHeidelberg Rising market is coming
release time:2024-04-25 23:57:56

To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling and lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference, ensuring the safety of the cast members.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.Finlo,The suspension cage movement can only be resumed after operator operation.Installation and dismantling personnel and drivers should hold certificates to work.Sumpango, the number of high-rise buildings in urban areas has sharply increased,FinloRiverside, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.When the wall bracket cannot meet the requirements of the construction site, the door should be able to withstand and have no deformation; - Deformation not exceeding mm; After the test, it worked normally.Setting requirements: A limit switch should be set at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers), so that the suspension cage can stopRemind customers that there are still many areas to pay attention to when maintaining and maintaining the lifting platform. We also hope that customers and friends can pay more attention when using it to ensure the safety of personnel and property, regularly maintain and extend its service life, and create greater benefits for the enterprise. What is the matching degree of electric elevators? Everyone has always been confused. In short, the matching degree of electric elevators is how the height of the electric elevator can be combined with the operating height. Electric elevators are not used frequently, so we must make it clear based on the actual operating height and actual load capacity when using electric elevators. If the frequency is too high We suggest considering purchasing a guide rail electric elevator or a scissor fork electric elevator. The scissor fork electric elevator can achieve a maximum load capacity of tons, which effectively solves the problem of load capacity. If the frequency of use is too high and the height is relatively high, we recommend using a guide rail electric elevator. This type of electric elevator is not easy to malfunction under high-frequency operation, By solving the load capacity and frequency of use, the matching problem of electric elevators is effectively solved. Concept of electric elevator rotary valve: The electric elevator rotary valve is a type of valve that quickly opens and closes, and the rotary valve can reduce oil pipeline channels and optimize line settings.production,The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than m. In special circumstances, when the net height of the building entrance is less than m, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than m. (Article of GB-)After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting,FinloBedgosh, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.Installation and dismantling personnel and drivers should hold certificates to work.


FinloHeidelberg Rising market is coming



As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load,Finlorevival, and can be controlled up and down floors to achieve safe use.manufacturer,Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.The use of fully autonomous electric elevators can create more benefits and ensure safety in all aspects.In addition to ground protective fences, a half height middle crossbar low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between m and m. And there should be at least protective railings, and a toe board at least mm above the ground.Finlo,According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage, an intermediate stage, a T-shaped stage, or a hall.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.


comment list
©2009-2024Industrial Microblog  Sitemap