Peter kuytrubnieskiHebeiThe funding rate is still high
release time:2024-04-28 09:53:05

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, intermediate shafts and bearings, oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be - millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner ( # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, and the joints must not be loose. All joints must be tightened. Remove and disassemble the lowering valve of the lifting platform,Peter kuytrubnieskiSihu , blow out the plunger with compressed air, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.Peter kuytrubnieski,The noise of aluminum alloy electric elevators during operation is relatively low. If the noise is high,Peter kuytrubnieskiCatania, it is abnormal. Therefore, it is necessary to do a good job in troubleshooting, find the cause in a timely manner, and reduce dangerous accidentsSetting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.Ajax,Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.Setting requirements: Before starting work every day and changing shifts,Peter kuytrubnieskiAnam, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor position


Peter kuytrubnieskiHebeiThe funding rate is still high



Setting requirements: The installation and dismantling workers electricians, and other operators of construction electric elevators should have special construction operations.The upward movement of the hydraulic cylinder involves lifting heavy objects, and the return oil from the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve. The additional pressure relief valve is used for adjustment, and the pressure gauge reads the value when observing the pressure gaugeSpiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only -mm and a travel distance of up to m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.Discount,From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machineryThe connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.When applying a normal force of N to any position on either side of the door using a rigid mm square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding mm; After the test, it worked normally.


Peter kuytrubnieskiHebeiThe funding rate is still high



The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.Excellent quality,Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.Try to use this equipment in areas with wind force less than level five, and avoid using it when the wind force is too strong to avoid accidents.As a material loading and unloading equipment recognized by customers in the lifting platform, the guide rail hydraulic lifting platform is superior in terms of product, civil engineering, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.Peter kuytrubnieski,Small safe operation distance: Circuit voltage (kV) of external power lines<~~~ Small safe operation distance (m) Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, concealed engineering acceptance form, and concrete strength report.The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform, wide working platform, and high bearing capacity

comment list
©2009-2024Industrial Microblog  Sitemap