Hi! this isHousehold elevator manufacturer'S microblog, immediately open and listen to his latest developments!

Industrial MicroblogWhether it is called Weibo or sticky notes, these small voices recorded here will become unforgettable memories. Here, you can send messages anytime, anywhere through mobile phones, web pages, etc., and see friends all the time. attentionHousehold elevator manufacturerThe latest news.

Household elevator manufacturer(@938HP166090698)
User offline

http://www.ilovebotdf.com/?938HP166090698

male,山东省 济南市

86 13064022215

  1. RiminiSmall stage elevatorWhat are the parameters of elasticity

    The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.Rimini,In daily life, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?When the normal power supply is cut off, the lighting inside the non fire elevator has no power, immediately close the door and return to the first floor stationIf the elevator is in a downward direction, and automatically open the elevator door.The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.


    RiminiSmall stage elevatorWhat are the parameters of elasticity



    Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Overloaded elevators do not operate: The load of elevators is limited, and if they are overweight, they will alarm and generally cannot be started. Most passengers can also voluntarily exit.Restore the command button function in the cabin for firefighters to operate.Economic management,The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.


    RiminiSmall stage elevatorWhat are the parameters of elasticity



    The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Welcome calls ,When the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.. Different types of civil engineering traction elevators, screw elevators, and hydraulic elevators have different requirements for civil engineering. Common traction elevators require a certain amount of hoistway space, which can be made of concrete, steel structure hoistways, and glass curtain walls to create sightseeing elevators; The depth of the pit should be at least cm or more; Additionally, there are certain requirements for the height of the top floor.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.Rimini,RiminiHousehold traction small elevator,  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size,RiminiHousehold outdoor elevator on the third floor, door opening width, etc.), then consider the non-standard design of the elevator.Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.


    5An hour ago byWeb pagegreat  |   broadcast  |   comment   | Favorites
  2. KartanisetaVilla small household elevatorHow to become a qualified operator

    The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed,As elevator people, let's talk about elevator and elevator safety knowledge: The elevators we currently use include box type passenger elevators, escalators, and dedicated cargo elevators. Dedicated cargo elevators are installed due to special needs, and we don't use many of them. Now, let's take a look at the safety knowledge of box type passenger elevators and escalators: When we take escalators, Be sure to follow the safety instructions when riding on the elevator. Do not crowd or play around, hold onto the elevator firmly, fasten your shoelaces, and avoid getting them caught up.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.Ghaziabad,Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.For escalators that require intermediate support, as well as the range of support that can be added, and other parameters.The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.


    KartanisetaVilla small household elevatorHow to become a qualified operator



    The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Household elevators have gradually become an essential vertical transportation tool for modern single family, duplex, multi story, villa and other residential buildings, practical and convenient, and even a beautiful scenery in the home.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams,KartanisetaPrice of 5-story household elevator, steel beams can be considered to be added between the frames for rectification.Bidding,Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents,KartanisetaAutomatic sheet turnover machine, which make my heart feel uneasyThe safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.


    KartanisetaVilla small household elevatorHow to become a qualified operator



    The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.investment,There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.If there is a reserved shaft in the villa residential area the appropriate car model can be selected by comparing the width and depth of the elevator car based on the size, width, and depth of the shaft. If there is no reserved shaft, you can first choose the model of the elevator and create a new shaft based on the required reserved size space for different models.The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data,KartanisetaAluminum alloy lifting platform, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets, the spacing between ring beams, and the position of embedded parts. Then the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).Kartaniseta,The door closing button has no self maintenance function. During the designated maintenance period the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.During the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed, and on the other hand, if any problems occur, someone is also responsible.Machine room power supply: The power supply should be three-phase V, HZ and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturers


    17An hour ago byWeb pagegreat  |   broadcast  |   comment   | Favorites
  3. TheofokHousehold small elevator pricesStrict control of product quality

    Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Measurement of elevator and escalator shafts (III)Theofok,The elevator stops on a certain floor for a long time without moving or responding to external calls: it is possible that the elevator administrator has activated the driver operation function.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Torrent,Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator as the frequency of opening and closing the door in the elevator is high,TheofokHousehold seat elevator, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.In the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, which is beneficial for reducing noise and automatically open the elevator door if it is in the upward direction.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.


    TheofokHousehold small elevator pricesStrict control of product quality



    The requirement for the shaft is that it should not be plastered, but there should be no protruding foreign objects.Household elevators have gradually become an essential vertical transportation tool for modern single family duplex, multi story, villa and other residential buildings, practical and convenient, and even a beautiful scenery in the home.For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform, and other parameters.index,Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyDuring the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed, and on the other hand, if any problems occur, someone is also responsible.The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.


    TheofokHousehold small elevator pricesStrict control of product quality



      “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.Trustworthy,The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesElevator Tip : Why elevators can trap people? Every elevator door on each floor has a safety switch, which can trigger the elevator to shut down in case of any abnormality. The elevator getting stuck is actually when the system detects an abnormal signal and triggers a protective device,TheofokStage curtain elevator, like braking to stop.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss and there should be embedded steel plates.Theofok,Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.The front room of the fire elevator is equipped with indoor fire hydrants.


    09092023930042020pm23 16:27 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  4. KasselStage elevatorWhat are the continued rise resistance
    KasselFully automatic high-altitude reclaimer,

    When the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise,The gantry elevator is used in the door legs of large gantry cranes to transport workers and maintenance components inside the gantry craneThe door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected,KasselElectric high-altitude reclaimer, refueled, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.Faro Airport,If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data,KasselStage hydraulic lifting platform, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to and special attention should be paid to moving parts such as counterweights and wire ropes).


    KasselStage elevatorWhat are the continued rise resistance



    For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform, and other parameters.The elevator stops on the first floor and the door does not move: the fire emergency landing function of the elevator is triggered by smoke or thermal sensors inside the building.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.The cost is reasonable,The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.


    KasselStage elevatorWhat are the continued rise resistance



    Measurement of elevator and escalator shafts (III)How much is it,To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment and the alignment of handrail turns during continuous arrangement.These phenomena are not elevator malfunctions. When the elevator is fully loaded, the elevator does not stop: to avoid overloading, the elevator car no longer responds to the next station's outbound call.The call button on each floor is no longer working, and the call is cut off.Kassel,To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, and the alignment of handrail turns during continuous arrangement.For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform, and other parameters.If the elevator is in a downward direction immediately close the door and return to the first floor station, and automatically open the elevator door.


    09092023930092020am23 09:00 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  5. Polly5-story household elevator smallIndustry highlights

    During the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed, and on the other hand, someone is also responsible.When the normal power supply is cut off, the lighting inside the non fire elevator has no power,PollyVertical obstacle free lifting platform, while there is still lighting inside the fire elevator.Polly,As elevator people, let's talk about elevator and elevator safety knowledge: The elevators we currently use include box type passenger elevators,PollyAutomatic sheet turnover machine, escalators, and we don't use many of them. Now, let's take a look at the safety knowledge of box type passenger elevators and escalators: When we take escalators, Be sure to follow the safety instructions when riding on the elevator. Do not crowd or play around, hold onto the elevator firmly, fasten your shoelaces, and avoid getting them caught up.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.Hegang,If the elevator is in a downward direction, immediately close the door and return to the first floor station and automatically open the elevator door.Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Measurement of elevator and escalator shafts (III)


    Polly5-story household elevator smallIndustry highlights



    Machine room power supply: The power supply should be three-phase V HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturersThe difference between home elevators and ordinary public elevators is that the focus of home elevators and ordinary public elevators is different, with some indicators significantly reduced. For example, which is much lower than that of ordinary public elevators. Home elevators do not need to consider the issue of passenger flow, and the lifting speed is slower, ensuring safety. The lifting speed is generally between . to .m/s, and running smoothly.Measurement of elevator and escalator shafts (III)Quality management, and there should be embedded steel plates.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling, it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.


    Polly5-story household elevator smallIndustry highlights



    Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height,PollyAluminum alloy movable lifting platform, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The cost is reasonable,Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.Slide elevators are installed inside buildings and are often used parallel to buildings and sidewalksPlease note that there should be a space of over mm left on both sides of the escalator and when arranged in parallel, there is no restriction between the two escalators.Polly,Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling, it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.


    09092023930031919pm23 15:03 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  6. WatfordDuplex villas stacked with household elevatorsQuality Index

    There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room,WatfordHydraulic flipper manufacturer, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.Watford,The difference between home elevators and ordinary public elevators is that the focus of home elevators and ordinary public elevators is different, with some indicators significantly reduced. For example, the load capacity of home elevators does not exceed kg, which is much lower than that of ordinary public elevators. Home elevators do not need to consider the issue of passenger flow, and the lifting speed is slower, ensuring safety. The lifting speed is generally between . to .m/s, and running smoothly.If the elevator is in a downward direction immediately close the door and return to the first floor station, and automatically open the elevator door.Custoias,Machine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, including: home elevator manufacturersb. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.


    WatfordDuplex villas stacked with household elevatorsQuality Index



    The call button on each floor is no longer working, and the call is cut off.If there is a reserved shaft in the villa residential area, the appropriate car model can be selected by comparing the width and depth of the elevator car based on the size, width, and depth of the shaft. If there is no reserved shaft,The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degrees


    WatfordDuplex villas stacked with household elevatorsQuality Index



    When the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.Project scope,If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.In daily life,WatfordPrice of hydraulic flipper, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?Machine room power supply: The power supply should be three-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business and the lighting power supply should be single-phase V, including: home elevator manufacturersWatford,The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.) then consider the non-standard design of the elevator.


    09092023930011616pm23 13:27 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  7. Hodmezowa sahliStage banner elevatorTeach you how to maintain

    Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableHodmezowa sahli,Overloaded elevators do not operate: The load of elevators is limited, and if they are overweight, they will alarm and generally cannot be started. Most passengers can also voluntarily exit.When the normal power supply is cut off, the lighting inside the non fire elevator has no power,Hodmezowa sahliHousehold seat elevator, while there is still lighting inside the fire elevator.Kaluga,The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified or has been completed, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.


    Hodmezowa sahliStage banner elevatorTeach you how to maintain



    Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.When passengers are riding on the escalator, they may lose their balance and fall due to leaning against the skirt board on the side of the escalator, which does not move,Hodmezowa sahliRear flip hydraulic flipper, but their feet move with the steps. Especially when carrying a lot of packages while taking the elevator, it is more likely to fall on the escalator due to the inability to hold the handrail properly. So, when riding on the escalator, and do not lean against the skirt board on the side of the escalator.There is a dedicated fire telephone in the fire elevator car.new product,The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.


    Hodmezowa sahliStage banner elevatorTeach you how to maintain



    The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesVariable cost,For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, and other parameters.When wearing high heels, be careful not to step on the gap between the pedals, as not wearing shoes is more likely to be pinched by the toothed plate.Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors,Hodmezowa sahliFully automatic hydraulic tipping machine hopper, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Hodmezowa sahliThe door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors) and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.


    09092023930121616pm23 12:00 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  8. IngolstadtVilla Home Elevator CostSeries function introduction

    The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform,The difference between home elevators and ordinary public elevators is that the focus of home elevators and ordinary public elevators is different, with some indicators significantly reduced. For example, the load capacity of home elevators does not exceed kg, which is much lower than that of ordinary public elevators. Home elevators do not need to consider the issue of passenger flow, and the lifting speed is slower, ensuring safety. The lifting speed is generally between . to .m/s, and running smoothly.Measure the length, width, and depth of the pit (if any),Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.To implement the arrangement of escalators and provide feedback in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise,IngolstadtSemi-automatic high-altitude reclaimer, but there should be no protruding foreign objects.


    IngolstadtVilla Home Elevator CostSeries function introduction



    Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.Elevator Tip : Why elevators can trap people? Every elevator door on each floor has a safety switch,IngolstadtHousehold elevator for a three story villa, which can trigger the elevator to shut down in case of any abnormality. The elevator getting stuck is actually when the system detects an abnormal signal and triggers a protective device, like braking to stop.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Production departmentThe front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.


    IngolstadtVilla Home Elevator CostSeries function introduction



    Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Discount,  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.The braking system of the elevator is usually closed, which means it is in the braking state when there is no power, and only when it needs to be turned on, will the power turn on the brakes. So as soon as there was a power outage, cut off the power and the elevatorCleaning and cleaning of elevator car guide shoes. As is well known,IngolstadtStage curtain elevator, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.Ingolstadt,The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.


    09092023930121515pm23 12:03 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  9. Zhang BoliTheater stage lifting platformOutstanding problems facing the market
    the operator only needs to provide the user with the standard elevator layout of the required elevator specifications

    Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Electrical components are roughly divided into screens, electrical switches for each safety circuit, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, waterproof, high-temperature resistant, sturdy and durable, safe and reliableZhang Boli,The elevator stops on the first floor and the door does not move: the fire emergency landing function of the elevator is triggered by smoke or thermal sensors inside the building.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled dust is removed,Zhang BoliAluminum alloy mast type lifting platform, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.Glasgow,The requirement for the shaft is that it should not be plastered,Zhang BoliFully automatic high-altitude reclaimer, which is beneficial for reducing noise, but there should be no protruding foreign objects.Measurement of elevator and escalator shafts (III)Brick concrete structure elevator shaft: For unfinished brick structure shafts users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.


    Zhang BoliTheater stage lifting platformOutstanding problems facing the market



    The call button on each floor is no longer working, and the call is cut off.Overloaded elevators do not operate: The load of elevators is limited, they will alarm and generally cannot be started. Most passengers can also voluntarily exit.During the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, the maintenance technology and quality are guaranteed, and on the other hand, if any problems occur, someone is also responsible.Economic management,Zhang BoliResidential use of indoor elevators in duplex buildings,Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.


    Zhang BoliTheater stage lifting platformOutstanding problems facing the market



    The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Inspection standard,Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Zhang Boli,The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesBrick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.


    09092023930031212pm23 15:00 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  10. DanbicaVilla Home Seat ElevatorHow to deal with the value of cranes encountering heatstroke

    The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.Danbica,Slide elevators are installed inside buildings and are often used parallel to buildings and sidewalksIf the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.Zupanja,b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.


    DanbicaVilla Home Seat ElevatorHow to deal with the value of cranes encountering heatstroke



    If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.As elevator people let's talk about elevator and elevator safety knowledge: The elevators we currently use include box type passenger elevators, escalators, and dedicated cargo elevators. Dedicated cargo elevators are installed due to special needs, and we don't use many of them. Now, let's take a look at the safety knowledge of box type passenger elevators and escalators: When we take escalators,DanbicaHydraulic barrier free elevator, Be sure to follow the safety instructions when riding on the elevator. Do not crowd or play around, hold onto the elevator firmly, fasten your shoelaces, and avoid getting them caught up.Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.Energy costs,The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.Electrical components are roughly divided into screens,DanbicaMobile aluminum alloy lifting platform,DanbicaBarrier free vertical lifting platform, electrical switches for each safety circuit, and door opening and closing of the elevator are all controlled by it, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant waterproof, high-temperature resistant, sturdy and durable, safe and reliableElectrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasy


    DanbicaVilla Home Seat ElevatorHow to deal with the value of cranes encountering heatstroke



    The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.consumption,There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.In daily life, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, and the cabin should be cleaned thoroughly.Danbica,Measurement of elevator and escalator shafts (III)Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.


    09092023930101212am23 10:27 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  11. MeretzHousehold villa small elevator manufacturerManagement System Research

    The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.Meretz,The elevator stops on a certain floor for a long time without moving or responding to external calls: it is possible that the elevator administrator has activated the driver operation function.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.Morphou,  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, etc.), then consider the non-standard design of the elevator.Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.


    MeretzHousehold villa small elevator manufacturerManagement System Research



    If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.The elevator stops on a certain floor for a long time without moving or responding to external calls: it is possible that the elevator administrator has activated the driver operation function.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified,MeretzSemi electric high-altitude reclaimer, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Excellent quality,The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.Electrical components are roughly divided into screens, electrical switches for each safety circuit, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, high-temperature resistant waterproof sturdy and durable, safe and reliable


    MeretzHousehold villa small elevator manufacturerManagement System Research



    If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.Industry management,The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition,MeretzAutomatic high-altitude reclaimer, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.When accidentally trapped in an elevator, one should remain calm, press the alarm bell inside the elevator, and call the elevator emergency rescue phone or community property phone for help. Do not open doors or mess with buttons, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Meretz,MeretzStage electric elevator,The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.Restore the command button function in the cabin for firefighters to operate.


    09092023930091111am23 09:03 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  12. KilkennyElevating platform stageAll kinds of functions you don't know

    The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.Kilkenny,These phenomena are not elevator malfunctions. When the elevator is fully loaded, the elevator car no longer responds to the next station's outbound call.There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.Ikere-Ekiti, and when arranged in parallel, there is no restriction between the two escalators.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.


    KilkennyElevating platform stageAll kinds of functions you don



    The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.If there is a reserved shaft in the villa residential area, the appropriate car model can be selected by comparing the width and depth of the elevator car based on the size, width, and depth of the shaft. If there is no reserved shaft, you can first choose the model of the elevator and create a new shaft based on the required reserved size space for different models.Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyinstall,There is a dedicated fire telephone in the fire elevator car.Restore the command button function in the cabin for firefighters to operate.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss,KilkennyHydraulic turnover machine, and there should be embedded steel plates.


    KilkennyElevating platform stageAll kinds of functions you don



    The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height,KilkennyHousehold elevator for a three story villa, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process,KilkennyElevating stage, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).production costs,Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyHousehold elevators must be regularly maintained to confirm their safety and whether they can continue to operate, while also repairing any faults and hidden dangers found.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.Kilkenny,Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Restore the command button function in the cabin for firefighters to operate.The front room of the fire elevator is equipped with indoor fire hydrants.


    09092023930060808pm23 18:22 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  13. Le MansHousehold villa elevator manufacturerThree common classification standards

    Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.Le Mans,Elevator does not close the door or repeatedly opens and closes the door: there are debris blocking the light curtain or door contact plate at the entrance or sill.To implement the arrangement of escalators and provide feedback,Le MansFully automatic hydraulic tipping machine hopper, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.Omaruru,Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasy


    Le MansHousehold villa elevator manufacturerThree common classification standards



    The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.These phenomena are not elevator malfunctions. When the elevator is fully loaded, the elevator car no longer responds to the next station's outbound call.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.superior quality,The front room of the fire elevator is equipped with indoor fire hydrants.Cleaning and cleaning of elevator car guide shoes. As is well known, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.


    Le MansHousehold villa elevator manufacturerThree common classification standards



    The front room of the fire elevator is equipped with indoor fire hydrants.Quality department,The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.When accidentally trapped in an elevator, one should remain calm, press the alarm bell inside the elevator, and call the elevator emergency rescue phone or community property phone for help. Do not open doors or mess with buttons, and patiently wait for rescue.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams steel beams can be considered to be added between the frames for rectification.Le Mans,During the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed,Le MansElevating platform stage, and on the other hand, if any problems occur, someone is also responsible.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room,Le MansStage main lifting platform, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).


    09092023930050808pm23 17:49 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  14. ColmarElevator for 3-story family villaShowcase of craftsmanship
    its safety cannot be guaranteed. If the elevator needs to be refueled without refueling

    Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, greatly shortening its service life and preventing normal use of the elevator.The call button on each floor is no longer working, and the call is cut off.Colmar,Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and to prevent skirts or pants from getting stuck.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side,ColmarAluminum alloy movable lifting platform, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Dar es Salaam,Machine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturersThere are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.b. When the old elevator cannot start: due to the inability to enter the shaft limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.


    ColmarElevator for 3-story family villaShowcase of craftsmanship



    Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work,ColmarStage hydraulic lifting platform,ColmarFixed stage elevator, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Home elevators are different from public spaces, such as professional home elevators, villa home elevators, home elevator manufacturers, small home elevators, and other special products. Old brands have advantages in price and guaranteed quality. Considering the limited installation space, lack of dedicated hoistways, and small lifting height, old brands price advantages, and guaranteed quality!If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.technological innovation, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.


    ColmarElevator for 3-story family villaShowcase of craftsmanship



    The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Quality assurance,The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.The braking system of the elevator is usually closed, which means it is in the braking state when there is no power, and only when it needs to be turned on, will the power turn on the brakes. So as soon as there was a power outage, the brakes closed and the elevator was braked in mid air. When the elevator descends abnormally, cut off the power and the elevatorThere is a dedicated fire telephone in the fire elevator car.Colmar,Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.In the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, the elevator should immediately stop on the floor without opening the door, return to the first floor station, and automatically open the elevator door if it is in the upward direction.


    09092023930030808pm23 15:36 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  15. AboniFamily villas and elevatorsMarket trend

    Measure the length, width, and depth of the pit (if any), width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Aboni,Elevators are used to transport firefighters, passengers, and fire-fighting equipment in the event of a fire. They are used to transport frozen goods in large cold storage or refrigeration workshops. However, they need to meet the requirements of sealing the door leaves and guide rails at the moving parts. Professional household elevators, villa household elevators, household elevator manufacturers, and small household elevators have stable, safe, reliable, and maintenance free performance, and their technical level has reached the domestic level, Meet the advanced level of international similar products and immersion requirementsIf the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.Nynashamn,For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform, and other parameters.Electrical components are roughly divided into screens, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, with a large quantity and excellent quality at a reasonable price. It is fire-resistant,AboniHydraulic flipper manufacturer, waterproof, high-temperature resistant, sturdy and durable, safe and reliableThe requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.


    AboniFamily villas and elevatorsMarket trend



    The call button on each floor is no longer working, and the call is cut off.Elevator Tip : Why elevators can trap people? Every elevator door on each floor has a safety switch, which can trigger the elevator to shut down in case of any abnormality. The elevator getting stuck is actually when the system detects an abnormal signal and triggers a protective device, like braking to stop.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise but there should be no protruding foreign objects.index,Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high,AboniFully automatic high-altitude reclaimer, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel,AboniAluminum alloy movable lifting platform, there is no restriction between the two escalators.


    AboniFamily villas and elevatorsMarket trend



    Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.How much does it cost?,The call button on each floor is no longer working, and the call is cut off.The seat elevator person sits on a chair driven by an electric motor, and the button on the chair handle causes the power drive device at the bottom of the chair to drive the person chair up and down along the guide rail of the staircase railingIf the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.Aboni,The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesIf the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.


    09092023930020808pm23 14:20 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  16. SeksadStage elevatorPrecautions before use
    but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing

    Electrical safety. Faulty elevators have multiple safety devices, while others have encountered situations where elevator buttons malfunction and the display screen is black,SeksadSingle and double column aluminum alloy lifting platform, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyIf the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.Seksad,The elevator stops on the first floor and the door does not move: the fire emergency landing function of the elevator is triggered by smoke or thermal sensors inside the building.Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator,SeksadMobile aluminum alloy lifting platform, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work,Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.


    SeksadStage elevatorPrecautions before use



    The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.The seat elevator person sits on a chair driven by an electric motor, and the button on the chair handle causes the power drive device at the bottom of the chair to drive the person chair up and down along the guide rail of the staircase railingAttention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling,SeksadStage main lifting platform, it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.Price,When the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.


    SeksadStage elevatorPrecautions before use



    The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.agent,For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform and other parameters.The seat elevator person sits on a chair driven by an electric motor, and the button on the chair handle causes the power drive device at the bottom of the chair to drive the person chair up and down along the guide rail of the staircase railingWhen the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.Seksad,Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and the call is cut off.Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.


    09092023930010808pm23 13:35 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  17. MaceResidential use of indoor elevators in duplex buildingsWhere to find

    There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.Mace,When accidentally trapped in an elevator, one should remain calm, press the alarm bell inside the elevator, and call the elevator emergency rescue phone or community property phone for help. Do not open doors or mess with buttons, and patiently wait for rescue.If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.Jabalpur,Measure the length, width, and depth of the pit (if any) and observe whether there are grooves and embedded parts at the support beam.Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyThere is a dedicated fire telephone in the fire elevator car.


    MaceResidential use of indoor elevators in duplex buildingsWhere to find



    Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.In daily life, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it,MaceVertical obstacle free lifting platform, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant,MaceHome villa sightseeing elevator, waterproof, high-temperature resistant, sturdy and durable, safe and reliableHonest management,The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.


    MaceResidential use of indoor elevators in duplex buildingsWhere to find



    The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.reform,The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.The elevator suddenly descends to the bottom floor and resumes normal operation: After the elevator is powered off and reconnected, the leveling reference position needs to be re determined.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters,Machine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business including: home elevator manufacturersElectrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black,MaceElevating platform stage, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyTo implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.


    09092023930090808am23 09:24 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  18. TurkwanFixed lifting rotating stageMaterial selection

    Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableThe effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.TurkwanHome elevators are different from public spaces, villa home elevators, home elevator manufacturers, small home elevators, and other special products. Old brands have advantages in price and guaranteed quality. Considering the limited installation space, lack of dedicated hoistways, and small lifting height, the design pursues simplicity and miniaturization, and the existence of computer rooms is not necessary. Long term promotion of home elevator manufacturers old brands, price advantages, and guaranteed quality!Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Kot Addu,Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Measurement of elevator and escalator shafts (III)  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size,TurkwanCustomized household small elevator, door opening width, then consider the non-standard design of the elevator.


    TurkwanFixed lifting rotating stageMaterial selection



    Measurement of elevator and escalator shafts (III)The gantry elevator is used in the door legs of large gantry cranes to transport workers and maintenance components inside the gantry craneAttention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling, it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.Industry managementTower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Cleaning and cleaning of elevator car guide shoes. As is well known the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.


    TurkwanFixed lifting rotating stageMaterial selection



    The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Online consultation, brand elevators must have third-party testing, and elevators that have been inspected by professional organizations are safe, reliable, and guaranteed to be used with peace of mind. In addition, when choosing to purchase villa elevators, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward,TurkwanRotating lifting stage, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableTurkwan,Electrical components are roughly divided into screens electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableMeasure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and there should be embedded steel plates.


    09092023930080808am23 08:51 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  19. OluPrice of 5-story household elevatorBriefly describe daily failures and solutions

    The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door,OluFully automatic hydraulic pressure for plate rolling machine, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Olu,The braking system of the elevator is usually closed, which means it is in the braking state when there is no power, and only when it needs to be turned on, will the power turn on the brakes. So as soon as there was a power outage, the brakes closed and the elevator was braked in mid air. When the elevator descends abnormally, cut off the power and the elevatorThe safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Sudan,  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force,OluHousehold elevator, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed,OluHousehold elevator for a three story villa, and on the other hand, if any problems occur, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.When encountering abnormal elevator operation, you can call the repair hotline to consult with the maintenance personnel or inform the service center to handle it. Do not take unauthorized measures to avoid causing greater harm to the elevator or even causing casualties.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Test method,The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.


    OluPrice of 5-story household elevatorBriefly describe daily failures and solutions



    The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.market,If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.Overloaded elevators do not operate: The load of elevators is limited, and if they are overweight, they will alarm and generally cannot be started. Most passengers can also voluntarily exit.Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Olu,Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.


    09092023930070707pm23 19:47 byWeb pagegreat  |   broadcast  |   comment   | Favorites
  20. JacksonvilleHousehold seat elevatorHistory of the industry
    JacksonvilleResidential use of indoor elevators in duplex buildings,

    Electrical safety. Faulty elevators have multiple safety devices, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyMaintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Jacksonville, and the button on the chair handle causes the power drive device at the bottom of the chair to drive the person chair up and down along the guide rail of the staircase railingMultiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Gaoyang City,The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Measurement of elevator and escalator shafts (III)


    JacksonvilleHousehold seat elevatorHistory of the industry



    The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.There are many similar situations in daily life, such as forcefully opening the door inside the car, causing the circuit to disconnect and forcing the elevator to stop, resulting in people being trapped. For example, if the elevator frequently enters and exits during decoration and falls into the crack of the door, the elevator hall door may not be tightly closed, and after several consecutive doors are opened and closed, the elevator will stop. Professional quality assurance for home elevator manufacturers. Discount activities are underway and new and old customers are welcome to come for consultationThe requirement for the shaft is that it should not be plastered, but there should be no protruding foreign objects.production costs which is beneficial for reducing noise,Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Brick concrete structure elevator shaft: For unfinished brick structure shafts, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator,JacksonvilleSelf walking aluminum alloy lifting platform, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.


    JacksonvilleHousehold seat elevatorHistory of the industry



    In the event of a fire,JacksonvilleStage main lifting platform, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, the elevator should immediately stop on the floor without opening the door, return to the first floor station, and automatically open the elevator door if it is in the upward direction.Where is itIf the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.Aircraft weighing tens or hundreds of tons in the elevator hangar are vertically lifted onto the airport runwayThe front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Jacksonville,Brick concrete structure elevator shaft: For unfinished brick structure shafts, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The front room of the fire elevator is equipped with indoor fire hydrants.To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.


    09092023930050707pm23 17:43 byWeb pagegreat  |   broadcast  |   comment   | Favorites