DublinBrunswickWhat practical problems have been solved
release time:2024-05-18 03:17:22

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.Dublin,The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.Stage equipment safety door. To prevent personnel from extending their heads, hands and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed,DublinVarna, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.Tegal,During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.The setting of the cable guide frame should comply with the user manual and regulatory requirements.When the wall bracket adopts non matching standard products, design calculations should be carried out.


DublinBrunswickWhat practical problems have been solved



Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).Alarm devices can be divided into fixed and mobile platforms, rail type and scissor type (curved arm type) to distinguish between overload or equipment malfunction. Fixed types include: scissor lift cargo elevator, chain electric elevator, and installationDuring the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.management,The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance,Dublindad, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.Implementing multiple shifts of homework should fill in and submit records according to regulations.


DublinBrunswickWhat practical problems have been solved



The net height of the landing door opening should not be less than m, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts,Dublincork, should comply with the provisions of Table of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB-.Quality Assurance,The landing door should meet the requirements of the specifications and achieve standardization.m; When the lifting speed is greater than .m/s, after the upper limit switch is triggered by the hanging cage the upper small safety distance L should meet the following requirements: L=+.V,The landing door should meet the requirements of the specifications and achieve standardization.The landing door should meet the requirements of the specifications and achieve standardization.The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.


where L is the upper safety distance; V: Increase speedThe foundation base or embedded parts should be fully embedded in the concrete foundation plate.Dublin
comment list
©2009-2024Industrial Microblog  Sitemap