AlkmarInstallation cost of cold storageProduct information
release time:2024-04-23 00:41:03

Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.Operating the unit: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.Alkmar,The refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. The warehouse has a wide range of temperature control. The selection, layout and wind speed field description of refrigeration equipment are suitable for the refrigeration needs of various goods. Equipped with perfect storage temperature active detection, recording and active equipment.The combined cold storage door starts frequently or does not start for a long time or does not stop for a long time, or stops before the storage temperature reaches.Jonkoping,The equipment configuration is reasonable and the service life of the quick freezing warehouse is long. The reasonable equipment configuration of the quick freezing warehouse can greatly prolong the service time of the quick freezing warehouse. Some compressors are easy to be damaged when they work at full load for a long time, so we try to use screw parallel units. The great advantage of this unit is that it can turn on all equipment, just like the shift at work, so that the compressor can work and rest in turn.During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use cm or cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to regulations, the foaming density of cold storage is per cubic meterThe drainage at the outlet of the cooling fan, the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.


AlkmarInstallation cost of cold storageProduct information



The refrigeration equipment in the fresh-keeping environment of the quick-frozen warehouse mostly adopts the single-stage compression refrigeration system, with freon as the refrigerant. The evaporation mode in the warehouse is the cooling fan, which can be ceiling type. If the number of warehouses is small and the volume does not exceed cubic meters, the refrigeration mode of the warehouse machine can be considered. If there are a large number of warehouses, the mode of multiple heads in parallel can be considered.Frequently check and acknowledge whether the voltage of the power supply meets the requirements, and the voltage should be V & plusmn; % (phase line). When the fresh-keeping warehouse equipment is not used for a long time, the main power supply of the fresh-keeping warehouse shall be cut off, and it shall be ensured that the fresh-keeping warehouse equipment is not affected by moisture, dust and other substances. The condenser on the refrigeration unit is simply contaminated, and the fresh-keeping warehouse shall be cleaned regularly according to the actual situation. To adhere to outstanding heat transfer.First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel,AlkmarPrice of medical cold storage, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector it shall be about mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.production,Polystyrene foam: polystyrene foam is a new type of synthetic thermal insulation material. It is a kind of plastic, with small density, light weight, strong heat insulation effect and excellent low temperature resistance. However, due to its cold shrinkage, it is not very convenient for installation.The cold storage shall be regularly overhauled and maintained so as to reduce the failure rate of the refrigeration unit and achieve good refrigeration effect.Application of parallel compressor in cold storage: the requirement of refrigeration capacity is large, and to refrigeration compressors under Malige need to be used on weekdays; Long term operation, large load peak valley difference and significant departmental load; Frozen and refrigerated objects are novel foods that are easy to decay and degenerate, and have strict requirements for temperature and humidity.


AlkmarInstallation cost of cold storageProduct information



A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.Quality riskThe insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.Air conditioning monitoring pan geographic air conditioning room monitoring system consists of front-end equipment, client / device app and PC large screen.When the cold storage is used for the first time or shut down for a long time, it is strictly prohibited to stack goods in the warehouse. The warehouse must be slowly reduced to the required temperature. For the low-temperature warehouse, it needs to be cooled in stages to avoid sudden changes in the temperature difference inside and outside the warehouse, resulting in the warehouse body.Alkmar,AlkmarCold storage installation company,AlkmarDesign and installation price of cold storage,Reasonable space: the power consumption of the cold storage is calculated according to the cold consumption of the cold storage, which usually includes two parts: the cold consumption during cargo cooling and refrigeration; It is the cooling consumption of the refrigeration room itself and operation management.How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.The cold storage board uses light polyurethane as the inner material of the cold storage board. The advantage of polyurethane is that the thermal insulation performance is very good. The exterior of polyurethane cold storage board is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is to prevent the temperature transmission of cold storage board due to large internal and external temperature difference, so as to make the cold storage more energy-saving and improve the working efficiency of cold storage.

comment list
©2009-2024Industrial Microblog  Sitemap