EmenHow much is the installation of cold storage per square meterCompany production
release time:2024-04-27 03:55:09

The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.During the early operation of the refrigeration unit, carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops, replace it with new oil in time so as to avoid bad compressor and reduce the service life of the compressor.Emen,For the installation of refrigeration unit, oil separator shall be installed for semi sealed or fully sealed compressor, and an appropriate amount of oil shall be added in the oil. When the evaporation temperature is lower than - ℃, gas-liquid separator and an appropriate amount of refrigeration oil shall be added.Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.Bilbao,With the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?Installation of cold storage, construction of cold storage, reliable and maintenance free performance. The technical level has reached the domestic level and the advanced level of similar international products. If there is a large amount of ice and water, it must be cleaned in time, and it must not be knocked during cleaning, so as not to damage the ground and affect the service life of the cold storage.Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software so it can only be used in less places, such as brine ice making and cold storage with constant temperature requirements.


EmenHow much is the installation of cold storage per square meterCompany production



Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.The electric cabinet shall be in strict accordance with the requirements of the drawing, and the power shall be connected for no-load test.Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate, compressor line is disconnected, fuse is blown, thermal relay acts, high voltage switch acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blockedTest conclusion,The overall construction achievements of the cold storage project have been put into use, and the service life can reach years.Compression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.Features of quick freezing warehouse: the quick freezing technology is advanced,EmenVegetable and fruit cold storage, the frost free quick freezing method is adopted the famous brand compressor and refrigeration accessories are configured, and the automatic frost is adopted. The method can only be used by microcomputer. The refrigeration system adopts green refrigerant, which belongs to the international advanced refrigeration technology in the st century.


EmenHow much is the installation of cold storage per square meterCompany production



Watertight polyurethane rigid foam has low water absorption good permeability to water vapor, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.Customer first,Pay attention to the energy saving of the lighting system: the lighting of the cold storage should be considered comprehensively according to the area, height and warehouse temperature of the cold storage on the basis of safety, science and rationality, from the perspective of energy saving and environmental protection. The lighting in the cold storage is concentrated in the working area.Establish a perfect computer network to realize the scientization of refrigeration supply chain distribution and traceability. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).Emen,The refrigeration equipment in the fresh-keeping environment of the quick-frozen warehouse mostly adopts the single-stage compression refrigeration system, with freon as the refrigerant. The evaporation mode in the warehouse is the cooling fan,EmenHow much is the installation of the freezer, which can be ceiling type. If the number of warehouses is small and the volume does not exceed cubic meters, the refrigeration mode of the warehouse machine can be considered. If there are a large number of warehouses, the mode of multiple heads in parallel can be considered.Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the refrigerant flow is too large, the evaporation pressure and evaporation temperature also increase, when the throttle valve is opened too small or blocked,EmenInstall a cold storage installation, the refrigerant flow will also decrease, the refrigeration capacity of the system will also decrease, and the decline rate of warehouse temperature will also slow down.Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and other special products, old brands, price advantages and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above degrees Celsius and will only be decomposed at higher temperatures. In addition, the ash formed on the surface of polyurethane will be in its foam, and this ash will help isolate the foam below. It can effectively prevent the spread of fire. Moreover, polyurethane will not produce harmful gas at high temperature.

comment list
  • Boxin Cleaning Service Liability Company

    EmenHow much is the installation of cold storage per square meter Very cost-effective! It is worth buying like everyone! worth having!

  • san hing co., ltd.

    Good seller, EmenHow much is the installation of cold storage per square meter things are very good. Come back in the future. You can buy with confidence.

  • Accounting Consulting

    After receiving the goods, I feel that the quality EmenHow much is the installation of cold storage per square meter is still relatively good, consistent with the seller’s description, very satisfied,

  • kai tong plastic products co., ltd.

    After receiving the goods, I feel that the quality EmenHow much is the installation of cold storage per square meter is still relatively good, consistent with the seller’s description, very satisfied,

©2009-2024Industrial Microblog  Sitemap