RecicaConstruction organization design of cold storage installationWhat are the common power grid disturbances
release time:2024-05-08 00:07:32

Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air,Evaporator is not only an exchanger for refrigeration and bulk cooling, but also a very important one. Its task is bulk cooling. It is mainly used for refrigeration and heat absorption in fresh-keeping warehouse. In the long-term work of the fresh-keeping warehouse, the fins of the evaporator will also be covered with dirt, mostly pasted with some sundries of the products. It is specialized in products and renewable resources. Its business includes: cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage. In addition dust and other things, but reaching a certain thickness will have an impact on the cooling of the fresh-keeping warehouse, If the refrigeration of the fresh-keeping warehouse becomes poor, it should be cleaned with a special cleaning agent for the evaporator.All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring, and power protection shall be provided for the box and each power branch.Rahimyar Khan,The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.Cold storage board, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, quality assurance, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.


RecicaConstruction organization design of cold storage installationWhat are the common power grid disturbances



Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications, and corresponding protection measures shall be taken for the installed equipment.The selection of refrigeration system is important to the quality of controlled atmosphere storage.Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.For more,RecicaCold storage installation Designer, please check,Because polyurethane sheet has excellent thermal insulation performance, it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production, construction and dry ceremony. - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).


RecicaConstruction organization design of cold storage installationWhat are the common power grid disturbances



Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.supply,Polyurethane foam: This is also a very common cold storage material. It has strong thermal insulation effect and strong mechanical strength. Now it is widely used and has a good application prospect.However, due to high labor intensity and incomplete defrosting, it has limitations.Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.Recica,Polyurethane with good fire resistance and flame retardancy is a kind of refractory and self extinguishing material after adding flame retardant. In case of fire it can be carbonized,RecicaCold storage Precooling, unlike flow burning and flashover like extruded board, it can be sealed as a whole after systematic fire prevention treatment to form non combustible products. - floor installation of cold storage: first level the floor,RecicaCold storage engineering, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor, and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.

comment list
©2009-2024Industrial Microblog  Sitemap