TrapaniDistribution transformer procurementFormalized development
release time:2024-04-19 23:24:42
TrapaniModel of electronic transformer,

Oil immersed transformer companyWhen the transformer is out of phase, if the second phase is blocked, there is still no sound when the second phase is sent, and there is sound when the third phase is sent; If the third phase is blocked, the sound will not change, as in the case of the second phase. There are three reasons for phase deficiency:Trapani,Transformer manufacturerIn the case of using dry-type transformer, customers must master the method of wiring. If there are problems in wiring, it is easy to cause common faults in application. So, what is the wiring mode of dry-type transformer?Quwaysina,The raw materials of Fushi blue can be used for bonding, so that the overall oil leakage of the connector can be greatly controlled; If the actual operation is convenient, the metal shell can also be bonded at the same time to achieve the purpose of leakage treatment.From the appearance, the packaging types are different. The transformer core and electromagnetic coil can be seen immediately for dry-type transformer, and only the shell can be seen for oil immersed transformer;Due to careless transportation of the transformer and the thin high-voltage conductor, such as discoloration, deformation offset, cracking, loosening,TrapaniRated current of 1600KVA box transformer, ignition smoke, oil leakage, broken strand disconnection, short-circuit fault marks, hanging of dirty things, which can be inspected according to the visual inspection method. Therefore visual inspection is one of the common methods of equipment inspection.Dry type transformer manufacturerHow much does it cost?,In the case of using dry-type transformer customers must master the method of wiring. If there are problems in wiring, it is easy to cause common faults in application. So, what is the wiring mode of dry-type transformer?There are many connection groups of dry-type transformers, and the selected structures and connections are also different. Then, what are the groups of dry-type transformers? How to carry out the connection? Or basically introduce it with the network of dry-type transformer manufacturers.It includes the performance and main uses of insulating layer materials, various insulating layer parts, component manufacturing processes and quality standards; Performance and main uses of various wires, coil inductance process of various ways of electromagnetic coil, overall suit process and quality standard of electromagnetic coil; Main performance parameters of ferrite core, cutting process of iron chip, production process and quality standard of electromagnetic shielding.


TrapaniDistribution transformer procurementFormalized development



The input and output three-phase power lines shall be connected to phase a, phase B and phase C respectively according to the color of yellow, green and red bus duct of transformer terminal board. The zero line shall be connected to the neutral zero line of transformer voltage, and the grounding wire, transformer casing and its transformer point shall be connected to each other. At ordinary times, the ground wire and zero wire are led out by the neutral wire of the transformer. (for example, the transformer box shall be matched with the ground wire mark of the shell and connected with each other). Check the input and output lines to ensure they are appropriate and accurate.Quality improvement,Generally speaking, the ignition emergency treatment method of oil immersed transformer is mainly to disconnect the oil immersed transformer, disconnect the switching power supply on each side, quickly invest the reserved oil immersed transformer and start the power supply system from scratch. Stop the operation of refrigeration equipment. Key oil immersed transformer ignition. When L-type oil immersed transformer and high voltage station oil immersed transformer are ignited, the generator set must be disassembled first.After the power transformer has been used for a long time, common faults of iron core will occur. Don't worry. Contact the transformer manufacturer, and the manufacturer will assign professional technicians for inspection. The main reasons are as follows:Sound, causing short circuit obstruction. If not handled properly, it will cause great damage.Trapani,In relay protection dry-type transformer, the disconnection of the fault point is related to each other. In a word, if there is any problem at a certain point, it will affect the whole power circuitCommon problems of tap changer of power transformerFrom the appearance, the packaging types are different. The transformer core and electromagnetic coil can be seen immediately for dry-type transformer, and only the shell can be seen for oil immersed transformer;

comment list
  • Design and Construction of Safety Technology Prevention Project

    Feels of value for money, service attitude is very good, TrapaniDistribution transformer procurement workmanship is very good, nothing fussy, all five points

  • airport company

    Ask, can I send TrapaniDistribution transformer procurement specific specifications, let me call you guys.

  • grid power company

    TrapaniDistribution transformer procurement Arrived, yes, this new model is indeed up to standard, very good

  • Large workshop door

    The quality is very good, exactly the same as the seller’s description, very satisfied, really like it, completely exceeding expectations, the delivery speed is very fast, the packaging is very carefu

  • Tongxing Pure Water Company

    TrapaniDistribution transformer procurement The quality is not bad, and the goods are delivered in time. I recommend you to buy it next time.

  • sea ​​blue machinery co., ltd.

    Now the business is not easy to do, can you give more discounts?